MasterLine 10
MasterLine 10
The product offering of MasterLine 10
windows is truly unique in its applicability:
inward opening windows, a full range of
transoms and frames, connection profiles
with Sliding and Curtain Wall system, but
also the design freedom that is offered
with the Renaissance and Deco profile
range.
The windows are offered with a Passive
House certificate!
The combination of all these features
makes MasterLine 10 the ideal solution for
domestic as well as public projects.
Test protocols
Technical data
TECHNICAL CHARACTERISTICS
|
|
|
|
FUNCTIONAL
|
RENAISSANCE
|
DECO
|
Min. visible width inward opening window |
Frame |
60mm |
Vent |
37mm |
Min. visible width inward opening
window-door
|
Frame |
60mm |
Vent |
67mm |
Min. visible width T-profile
|
87mm |
Overall system depth window
|
Frame |
97 mm |
107mm |
107mm |
Vent |
107mm |
Rebate height
|
27mm |
Glass thickness
|
Frame |
up to 88mm |
Vent |
up to 88mm |
up to 78mm |
up to 78mm |
Glazing method
|
60mm glass fibre reinforced noryl strips
|
PERFORMANCES |
|
ENERGY |
|
|
Thermal insulation (1)EN ISO 10077-2 |
Uf-value down to 0.78 W/m²K depending on the frame/vent combination and the glass thickness. |
|
COMFORT |
|
|
Acoustic performance (2)EN ISO 140-3; EN ISO 717-1 |
Rw (C; Ctr) = 46 (-1; -4) dB / 50 (-1;-2) dB, depending on glazing type |
|
Air tightness, max. test pressure (3)EN 1026; EN 12207 |
1
(150 Pa)
|
2
(300 Pa)
|
3
(600 Pa)
|
4
(600 Pa)
|
|
Water tightness (4)EN 1027; EN 12208 |
1A
(0 Pa)
|
2A
(50 Pa)
|
3A
(100 Pa)
|
4A
(150 Pa)
|
5A
(200 Pa)
|
6A
(250 Pa)
|
7A
(300 Pa)
|
8A
(450 Pa)
|
9A
(600 Pa)
|
E900
(900 Pa)
|
|
Wind load resistance, max. test pressure (5)EN 12211; EN 12210 |
1
(400 Pa)
|
2
(800 Pa)
|
3
(1200 Pa)
|
4
(1600 Pa)
|
5
(2000 Pa)
|
Exxx
(> 2000 Pa)
|
Wind load resistance to frame deflection (5)EN 12211; EN 12210 |
A
(≤ 1/150)
|
B
(≤ 1/200)
|
C
(≤ 1/300)
|
|
SAFETY |
|
|
Burglar resistance (6)EN 1627-1630 |
RC 1 |
RC 2 |
RC 3 |
This table shows possible classes and values of performances. The values indicated in red are the ones relevant to this system.(1) The Uf-value measures the heat flow. The lower the Uf-value, the better the thermal insulation of the frame.(2) The sound reduction index (Rw) measures the capacity of the sound reduction performance of the frame.(3) The air tightness test measures the volume of air that would pass through a closed window at a certain air pressure.(4) The water tightness testing involves applying a uniform water spray at increasing air pressure until water penetrates the window.(5)The wind load resistance is a measure of the profile’s structural strength and is tested by applying increasing levels of air pressure to simulate the wind force. There are up to five levels of wind resistance (1 to 5) and three deflection classes (A,B,C). The higher the number, the better the performance.(6) The burglar resistance is tested by statistical and dynamic loads, as well as by simulated attempts to break in using specified tools.